No |
Factors Due to Structural Design |
Mean |
Standard Deviation |
The Relative Weight (%) |
The Value of the Test |
P- Value |
Rank |
1- |
Non-compliance with the requirements of design codes and their updates. |
3.73 |
1.27 |
74.60 |
4.41 |
0.00 |
11 |
2- |
Ignoring soil investigation or Poor soil investigation leads to a wrong selection of foundation type. |
4.22 |
1.00 |
84.40 |
9.36 |
0.00 |
1 |
3- |
Ignoring environmental, weather condition, biological and chemical attacks. |
3.00 |
1.17 |
60.00 |
0.00 |
1.00 |
17 |
4- |
Ignoring building locations such as buildings located near the sea. |
3.27 |
1.13 |
65.40 |
1.85 |
0.07 |
14 |
5- |
Ignoring lateral loads effects (winds and earthquakes). |
3.39 |
1.05 |
67.80 |
2.85 |
0.01 |
13 |
6- |
Exceeding allowable deflection limits. |
3.91 |
1.01 |
78.20 |
6.87 |
0.00 |
6 |
7- |
Ignoring dynamic loads impact on structural stability. |
3.00 |
1.11 |
60.00 |
0.00 |
1.00 |
16 |
8- |
Ignoring the design of expansion, contraction, settlement joint and special construction joint. |
3.88 |
0.97 |
77.60 |
7.01 |
0.00 |
9 |
9- |
Inadequate concrete cover on reinforcement. |
4.07 |
1.02 |
81.40 |
8.08 |
0.00 |
2 |
10- |
Improperly locating conduits and pipe openings at critical structural locations. |
3.90 |
0.98 |
78.00 |
7.06 |
0.00 |
7 |
11- |
Insufficient sizing of structural elements such as reducing the size of columns, the size of reinforcement bars and foundations. |
3.98 |
1.20 |
79.60 |
6.31 |
0.00 |
3 |
12- |
Misjudgment in design leading to assumptions or decisions that are not consistent with the actual behavior of the structure. |
3.64 |
0.89 |
72.80 |
5.58 |
0.00 |
12 |
13- |
A roof design without inverted beams, which allows water intrusion. |
3.86 |
1.14 |
77.20 |
5.84 |
0.00 |
10 |
14- |
Inadequate slab types and loading ways with no consideration for codes related rules especially in long spans and cantilevers. |
3.97 |
1.03 |
79.40 |
7.18 |
0.00 |
4 |
15- |
Designing residential buildings away from the municipality’s conditions and engineering association rules. |
3.90 |
1.30 |
78.00 |
5.32 |
0.00 |
8 |
16- |
Lack of technical specification references for residential buildings. |
3.93 |
1.09 |
78.60 |
6.50 |
0.00 |
5 |
17- |
Not defining adequate materials. |
3.16 |
1.17 |
63.20 |
1.01 |
0.32 |
15 |