Table 2: Evaluation of FA point of teeth distance in upper first molar, upper first pre-molar and upper first canine subject a dynamic (patient) and static (instron) stress with different materials.

- Upper First Molar (16-26) Upper First Pre-Molar (14-24) Upper First Canine (13-23)
Base-line distance in FA
point (mm)
54,1 43,8 37,7
Smart
Track®
Test Patient Stress Instron Stress Patient Stress Instron Stress Patient Stress Instron Stress
Value (mm) 56.11 55.20 44.84 44.66 38.21 38.51
Difference + 2,01 +1,1 +1,04 +0,8 +0.51 +0.81
PET-G Test Patient Stress Instron Stress Patient Stress Instron Stress Patient Stress Instron Stress
Value (mm) 56.21 54.73 44.86 44.44 38.12 38.04
Difference +2,11 +0.63 +1,06 +0,64 +0,42 +0.34
PET Test Patient Stress Instron Stress Patient Stress Instron Stress Patient Stress Instron Stress
Value (mm) 54.89 54.59 44.04 44.07 38.00 38.26
Difference +0,79 +0.49 +0,24 +0,27 +0,3 +0.56