The Open Drug Metabolism Journal




(Discontinued)

ISSN: 1874-0731 ― Volume 5, 2011

Examination of the Utility of the High Throughput In Vitro Metabolic Stability Assay to Estimate In Vivo Clearance in the Mouse



S Sarawek*, 1, L Li1, X.Q Yu1, S Rooney1, A Nouraldeen1, L Moran1, L.A Rodriguez2, J Zhang3, A.G.E Wilson1
1 Drug Metabolism, Pharmacokinetics and Toxicology, Lexicon Pharmaceutical Inc., the Woodlands, Texas, USA
2 Enterprise informatics, Lexicon Pharmaceutical Inc., the Woodlands, Texas, USA
3 Keystone Analytical, Inc, a PharmaNet Company, 401A Industrial Drive, North Wales, PA, 19454, USA

Abstract

In vitro determination of metabolic stability is routinely used to assess the overall metabolic liability of compounds and for prioritization for in vivo studies. If in vitro metabolic stability data could be used to reliably predict in vivo clearance (CL), it would add significant value in the selection of compounds for in vivo pharmacokinetic and pharmacology studies. We have evaluated the utility of our in vitro metabolic stability screening assay to estimate in vivo CL in the mouse. The in vitro mouse clearances (CLin vitro) of 146 structurally diverse compounds with metabolic stabilities > 30 %, were compared to mouse in vivo CL data. Approximately 45 % of the compounds showed agreement between in vivo CL and predicted CLin vitro within a 2-fold error criteria. The correlation appeared worse when correction for the extent of incorporation of plasma protein binding or both plasma and S9 bindings (i.e. ~14 % and~ 28 % agreement, respectively). Classification of the compounds into three groups based on in vivo CL (<30 mL/min/kg, 30-70 mL/min/kg, and >70 mL/min/kg) did not show any improvement between in vivo CL and predicted CLin vitro. The percentage of compounds falling within the 2-fold error criteria for low CL, moderate CL and high CL groups were 54, 31 and 24 %, respectively. In conclusion, our analysis suggests that in vitro metabolic stability data, as routinely obtained in early ADME screening protocols, does not demonstrate a strong correlation with or predictivity for, absolute in vivo CL in the mouse.



Article Information


Identifiers and Pagination:

Year: 2009
Volume: 3
First Page: 31
Last Page: 42
Publisher Id: TODMJ-3-31
DOI: 10.2174/1874073100903010031

Article History:

Received Date: 21/11/2008
Revision Received Date: 31/12/2008
Acceptance Date: 28/1/2009
Electronic publication date: 11/3/2009
Collection year: 2009

© Sarawek et al.; Licensee Bentham Open.

open-access license: This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.


* Address correspondence to this author at the Drug Metabolism, Pharmacokinetics, Toxicology and Pathology, Lexicon Pharmaceutical Inc., The Woodlands, Texas, USA; Tel: (281) 863 3267; E-mail:ssarawek@yahoo.com





INTRODUCTION

Drug discovery and development is both time consuming and expensive. A study by Adams and Brantner reported that cost of new drug development can vary from 500 million dollars to more than 2,000 million dollars, depending on the clinical indication, manufacturing, etc [1]. Therefore, to raise the efficiency, and reduce the attrition rate of the drug discovery and development process, a more cost-effective industrial practice is becoming increasingly critical. Determination of the metabolic stability of compounds using in vitro hepatic systems (e.g., S-9 fraction), is now common place in the pharmaceutical and biotechnology industries [2].

It has been suggested that determination of intrinsic CL (CLint) using these in vitro hepatic systems, provides a measure of in vivo CL [3,4]. For example, several studies have reported a good correlation between predicted CLin vitro and in vivo CL using hepatocytes and microsomes [3-5]. However, in contrast, a number of studies have also suggested problems with this approach. For example, Iwatsubo et al. (1997) reported a poor correlation between in vivo CL and in vitro CLint with a number of compounds tested in human liver microsomes [6]. Andersson et al. reported 3 out of 4 compounds with poor predictions of hepatic clearance using human microsomes [7]. Thus, the robustness, accuracy and precision of using metabolic stability data to predict in vivo CL remain the subject of significant interest.

High throughput S-9 metabolic stability determination is routinely used within the Pharmaceutical and Biotechnology Industries as a means to identify potential metabolic liabilities at an early stage. The potential of this assay to efficiently investigate the metabolic liability of large numbers of compounds provides significant value in compound prioritization and structure-activity relationships (SAR) for lead identification and optimization. In addition, if this in vitro data were capable of reliably estimating potential in vivo CL over a wide range of chemical structures, it would also be of significant value in the prioritization of compounds for the more time consuming and expensive in vivo pharmacokinetic (PK), pharmacodynamic (PD) and toxicology studies. However, an essential requirement is that the assay and data have relevance to, and robustness, to estimate in vivo CL. In this manuscript, we report on our studies with 146 compounds, in which we have investigated the reliability of the in vitro metabolic stability assay to assess in vivo PK performance, as determined by in vivo CL.

MATERIALS AND METHODS

Materials

All reagents used were of standard laboratory reagent grade or better. The 146 structurally diverse test compounds with metabolic stability greater than 30 % were obtained from Lexicon Pharmaceutical Company over the five years. Mouse liver S9 was obtained from Xenotech (Lenexa, KS). C57BL/6 albino male mice were bred by Lexicon Pharmaceutical Company.

Metabolic Stability Assay

The in vitro metabolic stability assay was performed as previously described [8]. Briefly, in one time point study, 146 test compounds at 10 µM is mixed with reaction mixture containing 0.45 mg/mL mouse liver S9 fraction, 3.3 mM glucose-6-phosphate/magnesium (Sigma Chemicals St. Louis MO), 0.4 U/mL glucose-6-phosphate dehydrogenase (Sigma Chemicals St. Louis MO). The reaction was initiated by adding 1 mM NADP+ (Sigma Chemicals St. Louis MO). After 60 min incubation at 37 °C, the reaction was terminated by adding equal volume of acetonitrile containing 0.5 µM verapamil (Sigma Chemicals St. Louis MO) as an internal standard. After protein precipitation, the supernatant was analyzed by LC/MS/MS. In multiple time points study, 27 compounds were selected from 146 compounds and tested at 1 µM. Reaction was terminated at 0, 10, 30, and 60 min respectively. Beside time point studies, substrate concentration study was performed using one time point method. 35 compounds were selected from 146 compounds and tested at 1 µM and 10 µM. The % remaining was calculated by comparing the amount of compounds at 60-min incubation or other time points with the amounts of compounds at time 0 min. The half life (t1/2) was obtained by linear regression of % remaining over 60-min or multiple time points. The precision of the experiment and sample analysis in our laboratory is reflected in inter-day comparisons with midazolam (Sigma Chemicals St. Louis MO) as a positive control, which exhibited a stability of 48.4% remaining, (n = 175, SD = ± 4.83 %, % CV = ± 9.98 %).

Plasma Protein Binding and S-9 Binding

Equilibrium dialysis assay was used to measure plasma protein binding and S-9 binding. 29 compounds were selected from 146 compounds for S9 binding study. Tested compounds (10 µM, v/v) were mixed with mouse liver S9 (0.5 mg/mL). The mixtures were subjected to equilibrium dialysis versus phosphate buffer saline (PBS) at 37 °C using HT Dialysis 96 well plate (HT Dialysis LLC, Gales Ferry, CT). Dialysis membranes, with molecular mass cutoff of 12 to 14 K (HT Dialysis LLC, Gales Ferry, CT), were used and the plates were incubated at 37 °C for 4 h. Dialysis experiments were done in duplicate. Once the dialysis period was completed, the S-9 and buffer samples were removed and analyzed by HPLC/MS/MS. Plasma protein bindings of 146 compounds were conducted with the same method as the S-9 binding study.

LogP and Polar Surface Area (PSA)

LogP and PSA were calculated using Scitegic Pipeline Pilot Version 7.0.1.

In vivo Animal Studies

Pharmacokinetics Studies

All mouse experimental procedures were reviewed and approved by the Lexicon Institutional Animal Care and Use Committee (IACUC). Generally, 8-12-week-old C57BL/6 (albino) male mice were used for all pharmacokinetic studies. Animals were housed in micro isolator cages in a temperature and light/dark cycle-controlled environment with access to standard chow diet and water ad libitum.

Four mice were used in each study. Compounds were dissolved in 0.1 % Tween 80 (Sigma Chemicals St. Louis MO) or other vehicles. Mice received a single intravenous dose of 1 mg/kg. Blood samples were collected from either retro-orbitally or from the saphenous vein using EDTA tubes at 0.08, 0.25, 0.5, 1, 2, 4, 6 and 24 h. Plasma was separated by centrifugation at 5000 rpm for 5 min and stored at – 20 °C until analysis. Samples were analyzed by LC/MS/MS.

Sample Analysis by LC/MS

The concentration of each compound in the blood plasma from the PK studies was determined by LC/MS/MS. Prior to analysis, the plasma samples were protein precipitated with ten volumes of acetonitrile:water (80:20) containing 1 ug/mL verapamil (Sigma Chemicals St. Louis MO.) as an internal standard. Upon addition of the acetonitrile/water mixture, the plasma was vortexed for 3 minutes and centrifuged for 10 minutes at 14000 rpm with a Beckman Coulter Micro II centrifuge. Calibration curves of the analytes in blood plasma were prepared over the range 1.3 ngv;mL to10,000 ng/mL and were protein precipitated as described above. The calibration curves for the analytes were linear over the range of the measured unknown concentrations. The precison intra-and inter-day of analytes were satisfactory with CV value less than 15%. The accuracy of the assay obtained with quality control samples containing 1.3, 46.3 and 1670 ng/mL analytes were between 85 % and 115 %. The liquid chromatography system consisted of a Thermo Electron MS Pump and a CTC HTS autosampler. The chromatography column was an Agilent SB C8, 2.1 mm x 15 mm, 3.5 µm particle size. The mobile phases used in the gradient chromatography methods were: A; water with 0.1 % formic acid: B; acetonitrile with 0.1 % formic acid. The gradient had the following time profile: 0 minutes, 95 % A; 0.5 minutes, 95 % A; 1.0 minutes, 5.0 % A; 2 minutes, 5.0 % A; 2.1 minutes 95% A; 2.5 minutes, 95% A. The chromatographic flow rate was 0.5 mL/minute and an injection volume was 10 μL. Mass spectrometry was performed with a Thermo Electron TSQ Quantum Ultra AM or an Applied Biosystems 3000 mass spectrometer. The analyte and internal standard peaks were monitored with single reaction monitoring mode (SRM). Positive mode electrospray ionization was used for most compounds; however, negative mode electrospray and negative mode atomospheric pressure ionization were used for some of the compounds in this study.

The analytical method to determine the levels of compound in the metabolic stability and protein binding studies has similar extraction and chromatography methods to those used for plasma analysis in the PK studies. The mass spectrometry methods generally involved single ion monitoring (SIM) with some compounds requiring SRM methods when more signal:noise was necessary.

Calculations of In Vitro Intrinsic Clearance (CLint, in vitro) and Predicted CL in vitro

The in vitro intrinsic clearance (CLint, in vitro) of tested compounds was calculated based on substrate disappearance rate in S9 as follow:


CLin vitro was predicted based on well-stirred model or parallel tube model with some modifications as shown in Table 1.

Percentages of prediction were calculated from the plot between the predicted and observed CL in linear scale. On this plot, dot-lines indicated 2-fold error on the perfect clearance prediction, a solid line. Compounds falling inside the 2-fold error were accepted as good predicted compounds.

Data Analysis and Statistics

WinNonlin Professional, version 5.0 (Pharsight Corporation, USA) was used to estimate Pharmacokinetic parameters of tested compounds. Clearance (CL) and volume of distribution at the steady state (Vss) were calculated according to non-compartmental methods. Statistics analysis was performed using nonparametric statistic test (GraphPad Prism®, version 4.0). Spearman coefficient factor r (r) was used to represent correlation.

RESULTS

The physicochemical properties and in vitro and in vivo ADME parameters, including plasma protein binding, metabolic stability using 10 µM substrate concentration and mouse in vivo PK data of 146 compounds of diverse chemotypes are summarized in Table [2]. PSA values were in the range of 45 to 159. LogP values varied between –1.9 to 6.4. The values of fu, plasma ranged from 0.001 to 1. The metabolic stability of these compounds spanned a wide range from 44.7 to 99.9 % stable. In vivo CL was in the range of 0.79 to 89.00 mL/min/kg and Vss varied between 0.19 to 40.9 L/kg.

Table 2

Values for In Vivo Clearance, Fraction Unbound in Plasma, Polar Surface Area, logP, Volume of Distribution, % AUCextrapolated, % Remaining in Metabolic Stability Study, Intrinsic Clearance and Predicted CL in vitro of 146 Compounds Using Model A, B, E and F




The possible relationship between in vivo CL and predicted CLin vitro was examined using both the well-stirred model (model A) and parallel-tube model (model E) are presented in Fig. (1) and Tables 2 and 3. For all 146 compounds, the percentage of compounds falling inside the 2-fold error was similar for the well-stirred and parallel-tube models, (i.e. 45 %). Using either the well-stirred model or parallel-tube model, approximately 27 % and 29% of the compounds were over and under predicted, respectively. A nonparametric statistic test was used to estimate the correlation between in vivo CL and predicted CLin vitrodue to the variability in the data. Spearman r was 0.26 for both the well-stirred and parallel tube models. These results indicated no significant correlation between predicted CLin vitro and in vivo CL. Incorporation of the plasma unbound fraction (model B and model F) did not improve the relationship, with both models showing approximately 14 % agreement between in vivo CL and pre-dicted CLin vitro. Spearman r for both models was 0.04 (Table 2 and Table 3).

Table 3

Percentages of Compounds Falling into Good Prediction, Under Prediction and Over Prediction and r Values Using Model A, B, E and F (N=146)




Fig. (1)

Plots between in vivo CL and predicted CL from mouse S9 (N = 146). A, Model A. B, Model B. C, Model E. D, Model F. Solid line represents lines of unity, and the area between the dot-lines represents an area within 2-fold error.



The effect of different substrate concentrations and sampling time points was also investigated to see if it would improve the correlation between in vivo CL and predicted CLin vitro. Using substrate concentrations of either 1 µM or 10 µM did not improve the correlation showing only 46 % and 26 % agreement, respectively. Spearman r for 1 µM and 10 µM substrates were -0.03 and -0.10, respectively (Fig. 2 and

Fig. (2)

Plots between in vivo CL and predicted CLin vitro from mouse S9 calculated from model A (N = 27). ○ represents 10 µM substrate concentration and ● represents 1 µM substrate concentration. Solid line represents lines of unity, and the area between the dot-lines represents an area within 2-fold error.



Table 4). The results also showed that calculation of t1/2 using either single or multiple time points produced comparable estimates of predicted CLin vitro (Fig. 3). To further analyze the data, a binary classification was applied to 146 compounds. The classifications were based on the extent of metabolic stability (i.e moderate 30-70% and high > 70%) as shown in Table 5. Compounds with in vitro metabolic stability < 30% were not included in this analysis, since they are rarely progressed to in vivo PK studies because of the high degree of metabolism and therefore have limited PK data available. The plots between in vivo CL and predicted CLin vitrocalculated from well stirred model (model A) are presented in Fig. (4). For 27 compounds, with moderate metabolic stability (30%-70% remaining), there was little apparent correlation between in vivo CL and predicted CLin vitro. The percentage of agreement and Spearman r were ~56% and -0.39, respectively. A similar finding was observed for the 119 compounds with high metabolic stability (>70% remaining). The percentage of agreement and Spearman r were ~43% and 0.17, respectively.

Table 5

Classification of 146 Compounds Based on Metabolic Stability Data. Percentages of Compounds Falling into Good Prediction, Under Prediction and over Prediction and r Values Using Model A




Fig. (3)

Plots between in vitro t ½ of one time point study and in vitro t ½ of multiple time-points study in metabolic stability assay using 1 µM substrate concentration (N = 27). Solid line represent the linear regression line with y = 1.1747 x - 7.3363 and R2 = 0.9652.



Fig. (4)

Plots between in vivo CL and predicted CLin vitro from mouse S9 calculated from model A. A, compounds with moderate metabolic stability (30%-70%). B, compounds with high metabolic stability (>70%). Solid line represents lines of unity, and the area between the dotlines represents an area within 2-fold error.



Incorporation of the extent of binding to the mouse liver S-9 was determined for 29 compounds. The extent of S9 binding ranged from 6.5 % to 97.3%. Well stirred model with plasma and S9 binding (Model C) was used to calculate predicted CLin vitro. The result showed that correction of the CLin vitro for the extent of S9 binding did not improve the correlation. In addition, correction for both plasma and S-9 binding together also failed to improve the relationship between in vivo CL and predicted CLin vitro(Fig. 5). The percentage of compounds falling inside the 2 fold error and Spearman r were 28% and 0.06, respectively (Table 6).

Table 6

Percentages of Compounds Falling into Good Prediction, Under Prediction and Over Prediction and r Values Using Model A, B, and C (N=29)




Fig. (5)

Plots between in vivo CL and predicted CLin vitro from mouse S9 calculated from well-stirred model (N=29). ● represents model A and ○ represents model C. Solid line represents lines of unity, and the area between the dot-lines represents an area within 2-fold error.



In general, over predicted compounds had lower Vss (1.35 ± 1.35 L/kg), lower in vivo CL (6.88 ± 4.76 mL/min/kg), lower plasma protein binding (74.77% ± 30.61%), lower PSA (90.46 ± 33.48) and had high metabolic stability (i.e. % remaining 76.5 % ± 14.6 %) compared with well predicted and under predicted compounds (Table 7). Inclusion of Vss and logP into the well-stirred model (model D) improved the agreement between predicted CLin vitroand in vivo CL to~ 59 % for over predicted compounds and to ~ 19 % for under predicted compounds, whereas, inclusion of Vss and logP worsened the agreement by 57 % for well predicted compounds (Fig. 6). Under predicted compounds were generally metabolically stable (~ 89 % remaining) and had clearance values of ~ 50 mL/kg/min.

Table 7

Means of In Vivo Clearance, Volume of Distribution, % Plasma Protein Binding, LogP and PSA. Groups were Classified Based on the Correlation Between In Vivo CL and Predicted CLin vitro Calculated from Model A




Fig. (6)

Plots between in vivo CL and predicted CLin vitro from mouse S9 calculated from well-stirred model (N=146).A, good prediction group. B, under prediction group. C, over prediction group. ● represents model A and ○ represents model D. Solid line represents lines of unity, and the area between the dot-lines represents an area within 2-fold error.



In an attempt to improve the relationship between predicted CLin vitroand in vivo CL, compounds were classified into 3 groups based on in vivo CL values (low: < 30 mL/min/kg , medium: 30-70 mL/min/kg and high: > 70 mL/min/kg) [9, 10]. The percentage agreement for compounds with CL < 30 mL/min/kg, CL values of 30-70 mL/min/kg, and CL > 70 mL/min/kg was 54 %, 31 % and 24 % respectively. Spearman r values for compounds with low, medium and high CL were 0.011, -0.039 and -0.512, respectively. These results showed that there was poor correlation between in vivo CL and predicted CLin vitrofor all groups, although the low CL group showed a slightly better prediction of CL compared with moderate and high CL groups. Most of compounds in the high CL group showed under prediction of CL (Fig. 7, Table 8).

Table 8

Classification of 146 Compounds Based on In Vivo CL. Percentages of Compounds Falling into Good Prediction, Under Prediction and Over Prediction and r Values Using Model A




Fig. (7)

Plots between in vivo CL and predicted CLin vitro from mouse S9 using model A (N=146).A, CL< 30 mL/min/kg. B, CL 30-70 mL/min/kg. C, CL > 70 mL/min/kg. Solid line represents lines of unity, and the area between the dot-lines represents an area within 2-fold error.



DISCUSSION

Earlier published studies have suggested that intrinsic CL obtained from in vitro metabolic studies can be used to predict in vivo CL [8,11,12]. The good correlation appears to have been observed generally with extensively metabolized compounds for which hepatic clearance was the major clearance mechanism. In general industry practice, compounds showing high metabolic instability (<30 % remaining) are usually not advanced into in vivo study. We have therefore examined whether the commonly used high throughput metabolic stability assay can provide a robust and reliable estimation of in vivo CL.

In this study, we have investigated the correlation between in vivo CL and predicted CLin vitrofor 146 structurally diverse compounds. The metabolic stability assay used to determine CLin vitrowas performed with mouse liver S9 and CLin vitrowas calculated using well-stirred or parallel tube models with three different iterations: 1) no binding parameters (Table 1, model A and E); 2) incorporating only plasma binding (Table 1, model B and F); 3) incorporating both plasma and S9 bindings (Table 1, equation C). The results of our studies have shown that compounds with moderate (30%-70% remaining) and high (>70% remaining) metabolic stability showed poor correlation between in vivo CL and predicted CLin vitrowhen used either well stirred model (model A) or parallel tubed model (model E). Incorporating plasma protein binding (model B and F) did not improve the correlation between in vivo CL and predicted CLin vitro, which is consistent with previous studies [3,7,8,13,14].

Table 1

Models Used to Calculate Predicted CLin vitro




The inclusion of both plasma protein binding and microsome binding has been suggested to be important in liver models [8,15]. However, our study showed that including both plasma binding and S9 binding did not improve a correlation between in vivo CL and predicted CLin vitro.

The use of the disappearance method to determine CLint is based on the concept that CLint is close to Vmax/Km when substrate concentrations are << Km, namely under linear condition. In addition to substrate concentrations, enzyme concentrations and incubation time are also important for linearity. In our study, we have used 10 µM substrate concentrations, mouse liver S-9 concentration of 0.45 mg/mL and a 60 min incubation time. This method is commonly used in the industry for the conduct of high throughput metabolic stability studies. Substrate and enzyme concentrations used in previous studies varied between 0.5 µM and 1 µM substrates and ranged from 0.2 mg to 10 mg microsomal protein/mL, respectively [8,11,16]. Although, our substrate concentration was slightly higher than has been used in some other studies, studies in which we have used a substrate concentration of 1 µM or with multiple time points showed insignificant improvement in the relationship between in vivo CL and predicted CLin vitro (Fig. 3 and Table 4).

Table 4

Percentages of Compounds Falling into Good Prediction, Under Prediction and Over Prediction and r Values of 35 Compounds Using 1 µM or 10 µM Substrate Concentrations in Metabolic Stability Study. Predicted CL was Calculated Based on Model A




CLin vitrocorrected with Vss and LogP (model D) could improve the prediction of CLin vitro for over predicted compound and under predicted compound. But, for well predicted compounds, using Vss and LogP showed poorer prediction of CL than without using Vss and LogP (model A). However, this model requires in vivo Vss data, and thus this approach would not be applicable for early screening approach and defeat the purpose of using in vitro data to predict in vivo CL.

The use of empirical scaling factor (SF) to improve the correlation between in vitro and in vivo data was used in the study of Ito and Houston [12]. The empirical SF was determined by the regression analysis to obtain the best fit between intrinsic CL in vivo and intrinsic CL in vitro. Our study showed that the ratio in vivo CL/ predicted CLin vitrovaried from 0.02 to 94. Therefore, a single scaling factor was not applicable to the structural diversity of the compounds used in our study or typically investigated in drug discovery.

The apparent poor agreement in our study between in vivo CL and predicted CLin vitro was similar to the observation of some others using microsomes, hepatocytes and S-9 from humans or rats. For example, Andersson et al. presented the prediction of hepatic CL using well-stirred model and CLint calculated from enzyme kinetic measurement. Three out of four compounds showed under, and overestimation of in vivo CL when including and excluding plasma protein binding [7]. Carlile et al. reported poor predicted CLint of some CYP2C9 substrates using human microsomes with the predicted/observed CLint ratios of 0.05-0.31 [17]. Masimiremnwa et al. found no correlation between in vitro half life in rat liver S-9 and measured blood CL in vivo of 48 compounds in the same chemical series [18]. Thus our results appear to be in agreement with the studies that have not shown good agreement between predicted CLin vitroand in vivo CL with a larger number of compounds and various chemotypes.

CONCLUSION

This study was specifically designed to investigate the utility of the high throughput metabolic stability assay to generate an estimate of CLint, in vitro and to estimate in vivo CL. The metabolic stability assay is run in generally high throughput mode over a wide range of chemical diversity and metabolic stability. Therefore if this approach is to have utility in estimating in vivo CL it must have generic applicability, robustness and accuracy in the prediction of in vivo CL. The results of our studies suggest that CLint, in vitro calculated from metabolic stability data obtained using mouse liver S9 could not reliably predict in vivo CL. The data in the literature is inconsistent in regard to the utility of predicting in vivo CL from CLint, in vitrowith reports showing both good and poor agreement. It is not readily apparent why these differences appear to exist in the literature in regard to the utility of CLint, in vitro to predict in vivo CL. In our studies it was also not readily obvious why some compounds did appear to correlate with in vivo CL data, and others did not. Certainly, some studies do suggest that inclusion of a scaling factor can improve the correlation [12]. However, it remains unclear whether such scaling factors have generic applicability or are chemotype specific. From our studies with a large number of chemicals and using diverse chemotypes, there does not appear to be a common scaling factor. If such scaling factors are chemotype specific, then their utility would be restrictive and would not meet the criteria for use of high throughput metabolic stability screening data in providing as estimate of in vivo CL. However, overall the results from our studies suggest that in vitro metabolic data from mouse liver S9 does not reliably predict in vivo metabolic CL. It is also not clear from the literature, whether metabolic stability data from other in vitro hepatic systems can be used reliably to predict in vivo CL over a diverse range of chemical entities. In conclusion, the currently employed in vitro high throughput screening approaches for the determination of metabolic stability do not appear to reliably predict in vivo CL.

ABBREVIATIONS

b.w.  = Body weight
CL  = Clearance
CLin vitro  = Clearance in vitro
CLint  = Intrinsic clearance
CLint in vitro  = In vitro intrinsic clearance
fu, plasma  = Fraction unbound in plasma
fu,S9  = Fraction unbound in S9
IV  = Intravenous
PSA  = Polar surface area
PK  = Pharmacokinetics
PD  = Pharmacodynamics
Qh  = Hepatic blood flow
SF  = Scaling factor
 = Half life
Vss  = Volume of distribution at the steady state

REFERENCES

Track Your Manuscript:


Endorsements



"Open access will revolutionize 21st century knowledge work and accelerate the diffusion of ideas and evidence that support just in time learning and the evolution of thinking in a number of disciplines."


Daniel Pesut
(Indiana University School of Nursing, USA)

"It is important that students and researchers from all over the world can have easy access to relevant, high-standard and timely scientific information. This is exactly what Open Access Journals provide and this is the reason why I support this endeavor."


Jacques Descotes
(Centre Antipoison-Centre de Pharmacovigilance, France)

"Publishing research articles is the key for future scientific progress. Open Access publishing is therefore of utmost importance for wider dissemination of information, and will help serving the best interest of the scientific community."


Patrice Talaga
(UCB S.A., Belgium)

"Open access journals are a novel concept in the medical literature. They offer accessible information to a wide variety of individuals, including physicians, medical students, clinical investigators, and the general public. They are an outstanding source of medical and scientific information."


Jeffrey M. Weinberg
(St. Luke's-Roosevelt Hospital Center, USA)

"Open access journals are extremely useful for graduate students, investigators and all other interested persons to read important scientific articles and subscribe scientific journals. Indeed, the research articles span a wide range of area and of high quality. This is specially a must for researchers belonging to institutions with limited library facility and funding to subscribe scientific journals."


Debomoy K. Lahiri
(Indiana University School of Medicine, USA)

"Open access journals represent a major break-through in publishing. They provide easy access to the latest research on a wide variety of issues. Relevant and timely articles are made available in a fraction of the time taken by more conventional publishers. Articles are of uniformly high quality and written by the world's leading authorities."


Robert Looney
(Naval Postgraduate School, USA)

"Open access journals have transformed the way scientific data is published and disseminated: particularly, whilst ensuring a high quality standard and transparency in the editorial process, they have increased the access to the scientific literature by those researchers that have limited library support or that are working on small budgets."


Richard Reithinger
(Westat, USA)

"Not only do open access journals greatly improve the access to high quality information for scientists in the developing world, it also provides extra exposure for our papers."


J. Ferwerda
(University of Oxford, UK)

"Open Access 'Chemistry' Journals allow the dissemination of knowledge at your finger tips without paying for the scientific content."


Sean L. Kitson
(Almac Sciences, Northern Ireland)

"In principle, all scientific journals should have open access, as should be science itself. Open access journals are very helpful for students, researchers and the general public including people from institutions which do not have library or cannot afford to subscribe scientific journals. The articles are high standard and cover a wide area."


Hubert Wolterbeek
(Delft University of Technology, The Netherlands)

"The widest possible diffusion of information is critical for the advancement of science. In this perspective, open access journals are instrumental in fostering researches and achievements."


Alessandro Laviano
(Sapienza - University of Rome, Italy)

"Open access journals are very useful for all scientists as they can have quick information in the different fields of science."


Philippe Hernigou
(Paris University, France)

"There are many scientists who can not afford the rather expensive subscriptions to scientific journals. Open access journals offer a good alternative for free access to good quality scientific information."


Fidel Toldrá
(Instituto de Agroquimica y Tecnologia de Alimentos, Spain)

"Open access journals have become a fundamental tool for students, researchers, patients and the general public. Many people from institutions which do not have library or cannot afford to subscribe scientific journals benefit of them on a daily basis. The articles are among the best and cover most scientific areas."


M. Bendandi
(University Clinic of Navarre, Spain)

"These journals provide researchers with a platform for rapid, open access scientific communication. The articles are of high quality and broad scope."


Peter Chiba
(University of Vienna, Austria)

"Open access journals are probably one of the most important contributions to promote and diffuse science worldwide."


Jaime Sampaio
(University of Trás-os-Montes e Alto Douro, Portugal)

"Open access journals make up a new and rather revolutionary way to scientific publication. This option opens several quite interesting possibilities to disseminate openly and freely new knowledge and even to facilitate interpersonal communication among scientists."


Eduardo A. Castro
(INIFTA, Argentina)

"Open access journals are freely available online throughout the world, for you to read, download, copy, distribute, and use. The articles published in the open access journals are high quality and cover a wide range of fields."


Kenji Hashimoto
(Chiba University, Japan)

"Open Access journals offer an innovative and efficient way of publication for academics and professionals in a wide range of disciplines. The papers published are of high quality after rigorous peer review and they are Indexed in: major international databases. I read Open Access journals to keep abreast of the recent development in my field of study."


Daniel Shek
(Chinese University of Hong Kong, Hong Kong)

"It is a modern trend for publishers to establish open access journals. Researchers, faculty members, and students will be greatly benefited by the new journals of Bentham Science Publishers Ltd. in this category."


Jih Ru Hwu
(National Central University, Taiwan)


Browse Contents




Webmaster Contact: info@benthamopen.net
Copyright © 2023 Bentham Open