Table 2: Effects of Acute Oxygen Supplementation and Training Program (TP) on WT in COPD Patients

Variables Before TP After TP
AIR O2 AIR O2
 Distance (m) 458.2 ± 20 489.6 ± 19.6† 512.4 ± 20.3* 537.9 ± 19.9*†
 SpO2 at rest (%) 93.2 ± 0.6 96.9 ± 0.4† 95 ± 0.8 97,1 ± 0.5†
 SpO2 at the end of the test (%) 81.1 ± 1.5 90.9 ± 0.7† 81.1 ± 1.4 91.3 ± 1†
 Dyspnoea at rest 1.3 ± 0.3 0.9 ± 0.3 0.7 ± 0.3* 0.8 ± 0.3*
 Dyspnoea at the end of the test 6.1 ± 0.6 5.5 ± 0.6† 5.6 ± 0.7* 4.7 ± 0.6*†
 HR at rest (bpm) 92 ± 2.8 90.4 ± 2.5 89.8 ± 2.7 90.6 ± 2.8
 HR at the end of the test (bpm) 117.7 ± 3 115.1 ± 3.4 119.3 ± 2.7 117 ± 3.4

Values are represented as mean ± SD.*: p<0.05 within group comparison before versus after rehabilitation.†: p<0.05 comparison between O2-WT and the corresponding AIR-WT.